Preventive and Corrective Maintenance
Control Panel
10/27/05 S4M Maintenance Manual 13291L-001 Rev. A
Figure 146 • Remove and Install the Control Panel
5. Remove the mounting screw and washers securing the control panel.
6. Tip the top of the control panel away from the main frame enough to release the two tabs
inserted into the base and then pull it out of the base.
7. Carefully guide the control panel cable and the take-label sensor cable, if installed,
through their access holes.
8. Is there a take-label sensor board in the old control panel?
1
Main frame
8
Star washer
2
Main logic board (MLB)
9
Control panel
3
J19
10
Tab
4
Control panel cable
11
Cable access hole
5
J2
12
Access hole
6
Mounting screw
13
Conduit
7
Split washer
If… Then
No Go to Install the New Control Panel on page 279.
Yes Continue with Remove the Take-Label Sensor Board on page 276.