Using AutoSense AutoSense sets the sensitivity of the
transmissive sensor, measures and stores the
form (label) and gap lengths. For more details
on media sensing see Appendix A, page A-2. To
activate the AutoSense feature:
Step 1 Load labels into the printer. Do not use the peel
mode. Printer power is ON.
Step 2 Press and hold the PAUSE and CANCEL but
-
tons for one (1) second.
Step 3 Release the CANCEL button only. Wait three
(3) seconds. Release the PAUSE button.
Step 4 The printer will advance 3-4 labels while per-
forming the adjustment. When the adjustment
is complete, a status summary label will be
printed and the printer will be placed in Diag-
nostic Dump mode.
Step 5 Press the FEED button to exit the Dump mode.
Installation & Operation
18 980412-001 Rev.A
PAUSE & CANCEL
FEED
PAUSE
4 MO3257 3.18.01
Serial port : 96,N,8,1
Image buffer size:245K
Fmem:000,0K,019.9K avl
Gmem:000K,0241K avl
E
I8,0,001 rY
S8 D12 R032,000 ZT UN
q0784 Q1227,034
Option:D
11 12 13
now in DUMP
mem:000K,0241K avl
Sample: DUMP Mode
Printout
3sec.
1sec.
PEEL
BATCH
Power On
Media Loaded
Batch Mode