Zebra SL5000r/T5000r Guide d'installation Page 78

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 84
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 77
Chapter 3 PGL
78
PGL
Multiple Read/Write Commands On One Label
When using RFID commands in PGL, it is only possible to use one
read and one write command in a single form at a time. To access a
single label with multiple reads or writes, split the job into multiple
forms where all but the last form has the NOMOTION flag set. This
will then apply each form to the same label.
Example
~NORMAL
~CREATE;TEST1;NOMOTION
RFRTAG;64
64;DF1;H
STOP
VERIFY;DF1;H;*TagBefore=*
END
~EXECUTE;TEST1
~NORMAL
~CREATE;TEST1
RFWTAG;64
10;B;*101010*
10;D;*255*
10;H;*FF*
10;D;*12*
24;H;*445654*
STOP
RFRTAG;64
64;DF1;H
STOP
VERIFY;DF1;H;*TagAfter=*
END
~EXECUTE;TEST1
~NORMAL