Programming
Status Reporting Commands
66
P1003636-001 TTP 7020™/TTP 7030™ Technical Manual 02/11/2009
Results in a 1-byte response representing the temperature of the Printhead.
Results in a 2-byte response representing the version of the installed bootware.
The first byte represents major versions, and the second byte minor versions.
ESC ENQ 011
Head temperature Enquiry
1B 05 0B hex
27 5 11 decimal
Example •
SendESC ENQ 11d
Readn
Where n is a value representing the approximate temperature in Celsius.
ESC ENQ 012
Bootware version Enquiry
1B 05 0C hex
27 5 12 decimal
Example •
SendESC ENQ 12d
Read<001><030>
That is, a response with the value <01h><30h> indicates version 1.48.
Note • The TTP 7020 and 7030 does not store boot program in the flash memory so this
query will always be answered with <000><000>.