TTPM2 Firmware No. 906/907-xxx
906-213 means program version 2.13, etc.
FW version
Change
906-213
Start of FW history.
907-214
This FW version has only been used in dual ticket track applications.
•
Handling of dual tracks modified.
•
Ticket will be erased magnetically before being striped or voided.
•
XON will be sent once every 30 second if XON / XOFF is selected.
906/907-216
•
Start up routine modified. Cutter no longer operates at start up since this
may damage a ticket inserted from the front in case of a power failure in
the middle of an operation.
•
Cutter can be initialized by the "3-button reset operation"
•
Time-outs are now implemented for the !L3 function.
•
Minor modifications to the front load sequence.
906/907-217
!L3 now answers with ACK if card is loaded correctly and with NAK + error code in
case of a load failure.
The following error codes have been defined:
•
- NAK + B No card inserted within 10 seconds after received !L3.
- NAK + C Card inserted and then removed.
- NAK + D Card jam when loading card (serious fault)
•
An error in FW version 2.16 caused problems if a ticket was read with !D
and then printed without sending a new !M command before the !P. The
ticket was then striped. This is now corrected.
906/907-218
•
Command !N has been introduced to allow encoding of up to
approximately 50 characters on track 2 in hexadecimal format.
Characters 0—9 and A—F are valid. The least significant bit is encoded
first. No additional characters are added by the TTPM. It is, therefore,
necessary to put approximately six ZERO digits at the beginning of the
data to be encoded. Any start bits, stop bits, or check digit also have to
be included in the data string.
•
Reading a ticket encoded with !N, by the use of the !D command, will not
work since !D expects a ticket to have a correct ISO format.
•
Read after write on track 2 has been slightly improved.
•
Cutter is now reset at power up if no ticket is present in any of the
sensors close to the cutter. This prevents a ticket from being accidentally
cut, but enables the cutter to be reset in the event of a failure, or after
maintenance.
906/907-219
•
Command !O added. Reads track 2 of the magnetic stripe and reports the
result by returning up to 240 characters (0 or 1) representing the bits
rack No decoding is made by the TTPM2 This command