Problem Diagnosis Solution
NO TAG Error Message
(Continued)
Tags have metal/aluminum
in them.
Confirm that the tags meet
requirements (i.e. no metal/
aluminum in them)
Reload with proper tags.
ZPL II giving insufficient
amount of retries.
Increase the number of retries in
the ZPL II commands.
Tag is bad. Load new tags.
PK TIMEOUT Error Message
An attempt was made to
communicate to the internal
hardware, but timed out.
Retry printing label.
Cycle power and try printing
label again.
Verify internal cabling
connections
Call service technician.
Other Error Messages
Problem not correctable by
User.
Call service technician.