EAS PARAMETERS 6 - 29
Sensormatic Request Messages
There are three EAS message types (communication, high voltage, and enable scan time) that can be
selected by scanning the EAS message parameters that follow.
•
Request Communication/Connection Message:
Enabling this feature allows communication with the control box.
•
Request Voltage Message:
Enabling this feature sends messages about dangerous voltage levels.
•
Request Scan Time Message:
This message is only available in Auto Interlock Mode. The messages sent check to validate scan time is
synchronized between the MP6000 and the control box.
When any of these message types are enabled, messages are sent between the MP6000 and the control box
periodically (approximately every 2 seconds). Error messages display on the 7-segment display. Refer to the
MP6000 Integrator Guide (p/n 72E-172632-xx) for error messages.
Options:
•
*Enable Communication/Connection Message
•
Disable Communication/Connection Message
•
*Enable Voltage Message
•
Disable Voltage Message
•
*Enable Scan Time Message
•
Disable Scan Time Message