1 - 58 MP6000 BAR CODE PROGRAMMING GUIDE
IBM USB Scale Default Response Status
Parameter #1286
An MP6200 (MP6000 configured with a scale) sends a 2-byte scale status to the IBM USB Point of Sale (POS)
system as the default setting. This parameter allows a user to program the MP6200 scanner/scale to send
either 2-byte scale status, or a 3-byte scale extended status.
Options:
*2-byte Scale Status - Extended Scale Status Disabled: The 2-byte scale status sent to the IBM POS
consists of the information shown in Table 1-2 and Table 1-3.
Table 1-2
Scale Status Byte 0
Bit Position Description
0 Flash update in progress (if flash update is implemented).
1 Configuration data response frame.
2 Extended status response frame.
3 Not defined (always 0).
4 Not defined (always 0).
5 Not defined (always 0).
6 Unacceptable command.
7 Device not ready to receive weigh commands.
Table 1-3
Scale Status Byte 1
Bit Position Description
0 0: US weigh mode.
1: Metric weigh mode.
1 0: Four digit weight.
1: Five digit weight.
2 Weight data not include/scale in motion.
3 Data value error (weight digits not in range 0-9).
4 Read error (timeout occurred trying to obtain valid weight/status).
5 Remote display required but not detected.
6 Scale hardware error.
7 Undefined command received (command reject).