11 - 256 MP6000 BAR CODE PROGRAMMING GUIDE
Redundancy Level
Parameter # 78
The MP6000 offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of
bar code quality. As redundancy levels increase, the MP6000’s aggressiveness decreases.
Select the redundancy level appropriate for the bar code quality.
Options:
*Redundancy Level 1
Redundancy Level 2
Redundancy Level 3
Redundancy Level 4.
Redundancy Level 1
The following code types must be successfully read twice before being decoded:
Redundancy Level 2
The following code types must be successfully read twice before being decoded:
Redundancy Level 3
Code types other than the following must be successfully read twice before being decoded. The following
codes must be read three times:
Redundancy Level 4
The following code types must be successfully read three times before being decoded:
Table 11-2
Redundancy Level 1 Codes
Code Type Code Length
Codabar 8 characters or less
MSI 4 characters or less
D 2 of 5 8 characters or less
I 2 of 5 8 characters or less
Table 11-3
Redundancy Level 2 Codes
Code Type Code Length
All All
Table 11-4
Redundancy Level 3 Codes
Code Type Code Length
MSI 4 characters or less
D 2 of 5 8 characters or less
I 2 of 5 8 characters or less
Codabar 8 characters or less
Table 11-5
Redundancy Level 4 Codes
Code Type Code Length
All All