Calibration
Auto Calibration
NOTE: The printer will not auto calibrate when you are using
pre-printed labels or pre-printed label backing. If you are using
thistypeofmedia,see“ManualCalibration.”
By default, this printer automatically sets the sensor levels for, and
determines the length of, the label you are using. To auto calibrate:
1.Loadthemediaaccordingtotheinstructionsin“LoadingtheMediain
Getting Ready to Print.
2.TurnontheprinterorpresstheFeedbuttoniftheprinterisalreadyon.
3. Some blank labels will feed, completing auto calibration.
4.IftheErrorLEDbeginsflashing,referto“ManualCalibration.”
Hints:
Auto calibration only works when you are using non-continuous media
(a gap, notch, or black mark separates each label).
When auto calibration is selected, it occurs when the printer is turned on
(if the printhead has been opened), whenever an error is cleared, or if the
battery (or other power source) has been removed.