Routine Care and Adjustments
Lubrication
13163L Rev. 3 5/20/2004 Z4Mplus/Z6Mplus User Guide 83
Lubrication
No lubrication is needed for this printer.
Fuse Replacement
A user-replaceable AC power fuse is located just below the AC power switch at the rear of the
printer. The replacement fuse is a 5 × 20 mm fast-blow style rated at 5 Amp/250 VAC.
To replace the fuse, complete these steps:
1. To replace the fuse, insert the tip of a flat blade screwdriver into the slot in the end of the
fuse holder end cap.
2. Press in slightly on the end cap and turn the screwdriver slightly counter clockwise. This
disengages the end cap from the fuse holder and permits removal of the fuse.
3. To install a new fuse, remove the old fuse and insert the new fuse into the fuse holder.
4. Push the end cap in slightly, then insert the tip of a flat blade screwdriver into the slot in
the end cap and turn clockwise to engage it.
Caution • Some commercially available lubricants will damage the finish and the
mechanical parts if used on this printer.
Electric Shock Caution • Before replacing the fuse, turn off the AC power switch, and
unplug the AC power cord.