Note: If only one pair of lights is flickering, it indicates that the
adjustment was not successful. Go back to step 1 and start
over.
8. Open the printhead.
9. Pull the media out of the printer until a label is positioned under the
printhead. Move the ribbon back to its normal position.
Note: Be sure that label is positioned between the upper and lower
Media Sensors.
10. Close the printhead.
11. Press the MODE key to print a Media and Sensor Profile and save the
new values (see Figure 7.4.).
12.PerformtheMediaCalibrationprocedurein“ConfigurationandCali-
bration.”
7-6 Zebra S-Series User’s Guide
Figure 7.4 Media Sensor Profile Sample Printout