P Command - Print
Description Use this command to print the contents of the
image buffer.
Syntax
Pp
1
, [p
2
]
Parameters p
1
=Number of label sets.
Range = 1 to 65535
p
2
=Number of copies of each label (used in
combination with counters to print mul
-
tiple copies of the same label).
Range = 1 to 65535
The P command cannot be used inside of a stored
form sequence. For automatic printing of stored
forms, use the PA command.
Examples: P1 :prints one label set
P2,1 :prints 2 label sets of one label each
P5,2 :prints 5 label sets of 2 labels each
3-76