RMAN-RWS-001 rev. B • RW Series Repair Procedures • 2-44 •
Replacement Kit RK17393-012- RW 420 Docking Plug
Installation Instructions
This kit includes the parts and documentation necessary to install the
RK17393-012 Docking Plug Kit, RW 420 in the RW 420 model printer. Read these
instructions thoroughly before attempting to install this kit.
The operator must wear a properly grounded ESD strap to perform the following
repair procedure.
Reference Materials
UMAN-RWS RW Series Users Guide
Tools Required
#0 or #1 Phillips Head Screw Driver
Cautions
Always turn the printer off before performing this procedure.
Remove the Docking Plug
1. Remove the two screws securing the Docking Plug and remove the plug. The
Docking Plug must be removed before the printer is used with the RW 420
Docking Cradle; it should remain installed at all other times.
Install the Docking Plug
1. Line the Docking Plug up with the Lower Housing. Note that there is a locating
tab on the Plug that only allows it to be installed one way.
2. Secure the Plug with (2) screws.
Locating tab on Docking
Plug faces this direction .
Plug, Docking
Contacts RW 420
p/n BA17082-1
Screw, Self-Tap M3
x 10 mm Pan Hd.
Phillips (2)
p/n TH-PTA023010-5