RMAN-RWS-001 rev. B • RW Series Repair Procedures • 2-66 •
4. Peel the backing off the bar sensor cable and adhere it in the groove on the
bottom of the Printer Frame.
5. Install the Printer Frame in the Lower Housing, again referring to procedure for
RK17974-007 if necessary. Avoid putting excess strain on the remaining cables
connected to the CPU Board.
6. Plug the Bar Sensor Cable into J2 (PAPER) on the CPU Board and lock the
connector.
7. Re-install or, if necessary, replace the Platen and Gear Assembly (refer to the
procedure for RK17974-002)
8. Install the Upper Housing, ensuring that you have re-inserted the LCD and
Keypad ex circuits. Also ensure you have re-installed the D-Rings between
the Upper and Lower Housings.
9. Reinstall the battery
10. Calibrate the Sensors.
Thecalibrationprocedurecanonlybeperformedbycertiedpersonnelusing
special equipment and software.
Using the gray and white swatches, follow the on-screen instructions on the unit
test and set-up software to properly calibrate the sensors. It is recommended that
the complete unit test procedure be performed whenever a sensor assembly has
been replaced.
Peel the adhesive backing off
the Sensor cable and apply
the Bar Sense Cable into the
groove in the bottom of the
Printer Frame.