RMAN-RWS-001 rev. B • RW Series Repair Procedures • 2-50 •
NOTES:Theconnectorforthemotorcableispolarized.Itwillonlytinonedirection.Donot
try to force the connector in place.
Flex cables install in zero insertion force (ZIF) connectors. Pull the connector open,
insert the cable, and close the connector to retain the flex cable.
Dress the motor cable away from mounting bosses so they won’t get pinched during
the next assembly steps.
3. Ensure that the latch release button moves in and out freely.
Secure the CPU Board. Secure the Controller Board in place with the (2) Screws
supplied in the kit.
4. Install the Upper Housing. Refer to the procedure for kits RK17393-008 and
RK18280-1 for more details.
Test the Printer
1. Install the Battery Pack.
2. Load the application. You must reload the printer’s original application les.
These les can be stored either on your local system or can be downloaded
from the factory’s database.
YoumusthaveauthorizationfromZebratoaccesstheapplicationlesfromthe
factory.
3. Calibrate the Sensors. Using the gray and white swatches, follow the on-screen
instructions on the unit test and set-up software to properly calibrate the
sensors.
Press Latch release
button while installing
Controller Board
J2
J10
J6
J5