Programming
Software command syntax
10/22/2008 TTP2100 Technical Manual P1003640-001
Set Several Parameters at Once
ESC & P <000> <FromPar><ParCount><Data>
FromPar is the parameter number to start writing and ParCount is the number of bytes being
sent. For every byte sent the parameter number is incremented.
The TOF sensor board has it’s own firmware that can be upgraded using this command.
This command should be used when you integrate firmware loading into your kiosk program.
Example • This example sets the first 5 tabs to 5, 10, 15, 20, and 25. (FromPar 15, ParCount
5).
<ESC>&P<000><015><005><005><010><015><020><025>«»
ESC & s n1
Load SPI Slave Firmware
1B 26 73 0A hex
27 38115 10 decimal
n1 SPI Slave address, for the sensor board the address is 10 dec.
<file> the bin file with the new firmware.
ESC NUL
Load Firmware
1B 00 Hex
27 0 Decimal
Note • Utility programs to load firmware into the printer are available from