3 - 10 MP6000 INTEGRATOR GUIDE
4. Remove the circular cap from the existing display and either discard, or keep it as a spare part.
Figure 3-7
Removing Circular Cap
5. Connect the cable from the new display to the RJ-11 port marked “To Slave” on the PCB in the existing
(single head) display.
6. Place the short pole extension of the new display into the vacant slot in the rear cover of the existing
display.
Figure 3-8
Short Pole Extension
Figure 3-9
Rotation Limiting Tab
NOTE There is a rotation limiting tab on the top and bottom surfaces of the pole extension (see Figure
3-9). These need to be fitted one side or the other of the mating projection in the rear cover. If not,
there may be difficulty replacing the existing front cover.