2 - 54 MP6000 INTEGRATOR GUIDE
RS-232 AUX 2
Checkpoint Interlock
AUX A-B (Stacked USB)
Table 2-12
RJ-45
Pin # Signal/Name Direction Description
1 N/C N/A No connection
2 5V Out
RS-232 scanner 5V supply
*
3 GND N/A Signal ground
4 TXD Out Serial TXD (±5.4V)
5 RXD In Serial RXD (±5.4V)
6 RTS Out Serial RTS (±5.4V)
7 CTS In Serial CTS (±5.4V)
8 N/C N/A No connection
9 N/C N/A No connection
10 12V/150mA Out Output for auxiliary device.
NOTE 150mA maximum available
between both AUX 1 and AUX 2.
* The total combined current for the USB and RS-232 peripheral ports should be less than
750mA total auxiliary current. Each individual port should not exceed 500mA.
Table 2-13
EAS Interlock Connector
Pin # Signal/Name Direction Description
1 Interlock Out Checkpoint EAS Interlock (5V 4mA PNP collector out)
2 GND N/A Signal ground
Table 2-14
Stacked USB Port
Pin # Signal/Name Direction Description
1 5V Out
USB 5V output
*
2 D- Bidirectional USB D-
3 D+ Bidirectional USB D+
4 GND N/A
Signal ground
* The total combined current for the USB and RS-232 peripheral ports should be less than 750mA
total auxiliary current. Each individual port should not exceed 500mA.