3 - 36 MP6000 INTEGRATOR GUIDE
e. Secure each coil with two screws (see Figure 3-43 on page 3-34).
5. Route the coil wires through the key hole on the side of the MP6000 for connection to the controller box.
Leave the wires free, under the MP6000, for a Sensormatic representative to make the connection to the
controller.
Figure 3-46
Routing the Coil Through the Key Hole
6. Replace the MP6000 tower bezel.
7. Replace the MP6000 platter.
8. Connect the Interlock cable (supplied by Sensormatic) to the J7, or J5 port.
Horizontal
Sensorrmatic
Cable Pinch
Point
NOTE The Interlock cable is one of the free cables noted in Step 5.