Vue de la page 131
4 - 2 MP6000 INTEGRATOR GUIDE
Scale Calibration Procedure (Scanner/Scale Configurations Only)
Follow the steps below to calibrate the scale.
Scale Configurations
Identifying Firmware Version
A new Calibration Entry Method is required for Firmware Version 3.4 and later. To determine the firmware
version on the scanner, depress and continue to hold the EAS button. The scanner firmware version number
displays on the internal 7-segment display.
The existing Calibration Entry Method
should be used for firmware version prior to firmware version 3.4.
NOTES
1. The 30 second timer, or 90 second timer for Firmware versions before 3.4 (see Identifying
Firmware Version), resets after each successful stage of the calibration procedure (not applicable
at the Step 5 - Calibration Success or Failure stage).
2. If a Sca
le Display is unavailable, the internal 7-segment one character display can be used as a
user interface to prompt a user through the steps of the scale calibration procedure.
3. T
he scale can be calibrated without a Scale Display. However, if a Scale Display is used Enable
Scale Display Configuration (page 4-15) must be scanned to enable the display and its port. The
default Scale Display config
uration is: Disabled.
4. The
MP6000 scanner/scale must remain powered for a minimum of 15 minutes after a cold power
start prior to performing the calibration procedure.
5. At an
y time during the calibration process: if the units of measure are modified (e.g., lb to kg), and
a 90 second timeout is completed, the Scale Display flashes CAL and the 7-segment display has a
U14 warning code (indicating Scale Out of Calibration).
Table 4-2
Scale Configurations
Description
Single interval 0.01 lb (0.005 kg), without calibration switch (model # ending in -06).
Dual interval 0.005 lb (0.002 kg) minimum verification interval, without calibration switch
(model # ending in -08).
IMPORTANT The MP6000 platter can be removed to see the model number of the scale. The model number is
printed on a label affixed to the right side of the bottom bar of the scale’s U frame. The last two digits
in the model number define the scale’s configuration (see Table 4-2).