Zebra MP6000 Spécifications Page 151

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 210
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 150
SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 21
User Interface Displays and Signals
Table 4-6
LEDs, and Beeper Sequences
Scale State
7-segment
Diagnostic Display
LED
(System)
Beeper
Sequence
Scale
Zero
Button
(LED)
Optional Scale Display
Scale disabled No change No change None OFF Blank
Scale normal -
stable with
weight
No change No change None; single
short beep after
weight request
from POS, if this
feature is
enabled.
Solid Green
ON
Weight reading
Under zero No change No change None Flashing All “- - - - -” (dashes)
Over range
condition (weight
is greater than
30.09 lb, or
weight is greater
than 15.045 kg)
No change No change None OFF EEEEE
Weight unstable No change No change None OFF Numerical values blank but
measurement unit icons (lb
or kg) remain on.
Scale Zero
button press
If zero operation fails
it scrolls
U12
Red
(Warning) if
zero
operation
fails on a
Scale Zero
button press;
otherwise, no
change
Click sound No change If successful weight reads
0 (zero) and <0> indicator
icon illuminates.
Scale out of
calibration
Scrolls fault code
U14
Red
(Warning)
None OFF Blinks CAL
Vue de la page 150
1 2 ... 146 147 148 149 150 151 152 153 154 155 156 ... 209 210

Commentaires sur ces manuels

Pas de commentaire