3 - 34 MP6000 INTEGRATOR GUIDE
To ensure smooth scanning, replace the platter, take a steel can (like a soup can), turn it over so
the harsher seam is facing down, and slide the can over the platter in the standard scanning
direction. The can must not catch on the checkstand or the platter when swept across all sections
of the platter, in the correct direction.
4. Route all cables through the checkstand as shown in Figure 3-3
.
5. Connect all cables to the MP6000 and POS, as needed (e.g., scale, Scale Display, Checkpoint antennas,
or Sensormatic coils, POS, CSS, etc.).
6. Power up the MP6000. Upon power up, the MP6000 verifies that all sub-systems, and auxiliary devices
are operational. If a fault condition exists, an error condition displays on the 7-segment display, and the
startup sequence halts. Power cycling is required after rectifying the problem. (See General Error and
Warning Codes on page A-5)
If a scale is present, warm-up time for the scale is 15 minutes (assuming room the temperature is
70° F/20° C).
Install Sensormatic Coils
The horizontal antenna is installed below the platter, on the middle housing, affixed to the housing with screws.
The vertical antenna is installed behind the vertical glass, also affixed to the scanner with screws. The coil tail
wires (with connectors) should be properly routed alongside the scanner to which the Sensormatic controller
box lead can connect.To install the Sensormatic coils:
1. Remove the MP6000 platter.Disconnect power to the MP6000.
2. Remove the MP6000 tower bezel by squeezing inward on both the left and right sides of the lower part of
the tower bezel, pushing its side snaps to disengage. Slide the tower bezel up and lift out. (See Figure 3-15
on page 3-17.)
Figure 3-43
Sensormatic Coil Screw Holes (Platter and Tower Bezel Removed)
3. Install the horizontal coil first:
IMPORTANT Most accessories (scale, Scale Display, Checkpoint interlock, Sensormatic coils, Sensormatic
RS-232 cable, CSS, and auxiliary RS-232 scanners) must be installed and connected to the
MP6000 prior to applying power to the MP6000.
Vertical Sensormatic
Coil Screw Bosses (#6)
Horizontal Sensormatic
Coil Screw Bosses (#6)