^FC
Field Clock (for Real Time Clock)
Description: The ^FC command is used to set the clock-indicators (delimiters) and
the clock mode, for use with the Real Time Clock hardware. This command must be
included within each label field command string each time the Real Time Clock
values are required within the field.
Format: ^FCa,b,c
Parameters:
a = primary clock indicator character
Accepted Values: Any ASCII character
Default Value: %
b = secondary clock indicator character
Accepted Values: Any ASCII character
Default Value: none this value cannot be the same as a or c.
c = tertiary clock indicator character
Accepted Values: Any ASCII character
Default Value: none this value cannot be the same as a or b.
Comments: The ^FC command will be ignored if the Real Time Clock hardware is
not present.