^FO
Field Origin
Description: The ^FO command sets a field origin, relative to the label home (^LH)
position. ^FO sets the upper-left corner of the field area by defining points along the
x-axis and y-axis independent of the rotation.
Format: ^FOx,y
Parameters:
x = x-axis location (in dots)
Accepted Values: 0 to 32000
Default Value: 0
y = y-axis location (in dots)
Accepted Values: 0 to 32000
Default Value: 0
Comments: If the value entered for the x or y parameter is too high, it could position
the field origin completely off the label.
ZPL II Programming Guide Volume One: Command Reference for X.10
125