~HU
Host Unsolicited
Description: This command will return the table of configured ZebraNet ALERT
settings to the host.
Format: ~HU
Example:
If the ~HU command is sent to the printer with existing ALERT messages set to go
to e-mail and SNMP traps, the data returned would look something like the
information below. Refer to ^SX for complete information on parameter settings.
J,F,Y,Y,,0
C,F,Y,Y,,0
D,F,Y,Y,,0
E,F,Y,N,,0
F,F,Y,N,,0
The first line indicates that condition B (ribbon out) is routed to destination C (e-mail
address). The next two characters, Y and Y, indicate that the “condition set” and
“condition clear” options have been set to yes. The next entry is the destination that
The last figure seen in the first line is 0, which is the port number.
Each line shows the settings for a different ALERT condition as defined in the ^SX
command.
ZPL II Programming Guide Volume One: Command Reference for X.10