^SX
Set ZebraNet ALERT
Description: The ^SX command is used to configure the ZebraNet ALERT system.
Format:^SXa,b,c,d,e,f
Parameters:
a = condition type
Accepted Values:
A = paper out
B = ribbon out
C = printhead over-temp
D = printhead under-temp
E = head open
F = power supply over temp
G = ribbon-in warning (direct thermal mode)
H = rewind full
I = defaulted printer
J = cut error
K = printer paused
L = PQ job completed
M = label taken
N = head element out
O = Reserved
P = Reserved
Q = power on
R = all errors
Default Value: If this parameter is missing or invalid, the command
will be ignored.
b = destination to route alert to (A through F)
Accepted Values:
A = serial port
B = parallel port
C = e-mail address
D = TCP/IP
E = UDP/IP
F = SNMP trap
Default Value: If this parameter is missing or invalid, the command
will be ignored.