Format: ^HWd:o.x
Parameters:
d = location to retrieve object listing
Accepted Values: E:, B:, R:
Default Value: DRAM
o = object name
Accepted Values: any 1 to 8 character name
Default Value: asterisk (*). A question mark (?) can also be used.
x = extension
Accepted Values: any valid 3-letter extension
Default Value: asterisk (*). A question mark (?) can also be used.
Example:
Listed is an example of the ^HR command to retrieve information from R:.
^XA^HWR:*.*^XZ
The printer returned the following information as the Host Directory Listing:
-DIR R:*.*
*R:ARIALN1.FNT 49140
*R:ARIALN2.FNT 49140
*R:ARIALN3.FNT 49140
*R:ARIALN4.FNT 49140
*R:ARIALN.FNT 49140
*R:ZEBRA.GRF 8420
-794292 bytes free R:RAM